{"created":"2023-06-20T13:43:15.978956+00:00","id":974,"links":{},"metadata":{"_buckets":{"deposit":"edc46fae-129e-490d-b83e-3e72b436d67b"},"_deposit":{"created_by":2,"id":"974","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"974"},"status":"published"},"_oai":{"id":"oai:fut.repo.nii.ac.jp:00000974","sets":["1"]},"author_link":["11861","11863","11862","11864"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-08-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"39","bibliographicPageEnd":"291","bibliographicPageStart":"287","bibliographic_titles":[{}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In the present study, sub-microliter sample introduction technique was developed for ICP atomic emission spectrometry. In order to introduce a 0.5-μl volume of sample solutions into an ICP, a tungsten-filament (WF) with a Λ shape was made for electrothermal vaporization instead of the WF with a conventional shape. The possibility of the simultaneous multi-element determination with a 0.5-μl volume of sample solutions was found by optimizing measurement conditions such as charging voltage for a capacitor and electric current for the dry of sample solution on the filament. Although the further improvement in reproducibility is required, the signal-to-background ratios in many elements were almost similar to those measured with a 5-μl volume of sample solutions.","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57375/00000968","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井工業大学"}]},"item_10002_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"TF00009427","subitem_relation_type_select":"NCID"}}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18844502 / 18844456","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 智一"}],"nameIdentifiers":[{"nameIdentifier":"11861","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森安, 貴信"}],"nameIdentifiers":[{"nameIdentifier":"11862","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, Tomokazu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"11863","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Moriyasu, Takanobu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"11864","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-12"}],"displaytype":"detail","filename":"kiyou3939.pdf","filesize":[{"value":"2.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kiyou3939.pdf","url":"https://fut.repo.nii.ac.jp/record/974/files/kiyou3939.pdf"},"version_id":"3521fc1b-ae8b-48e3-9934-d0c204b56b13"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ICP","subitem_subject_scheme":"Other"},{"subitem_subject":"分析","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ICP発光分光分析法のためのサブマイクロリットル試料導入法の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ICP発光分光分析法のためのサブマイクロリットル試料導入法の開発"},{"subitem_title":"Development of sub-microliter sample introduction technique for ICP atomic emission spectrometry","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-11-30"},"publish_date":"2009-11-30","publish_status":"0","recid":"974","relation_version_is_last":true,"title":["ICP発光分光分析法のためのサブマイクロリットル試料導入法の開発"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-20T14:21:44.786500+00:00"}