{"created":"2023-06-20T13:42:33.000472+00:00","id":65,"links":{},"metadata":{"_buckets":{"deposit":"6ff9cce0-2d32-4731-a5c8-03db03832a80"},"_deposit":{"created_by":2,"id":"65","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"65"},"status":"published"},"_oai":{"id":"oai:fut.repo.nii.ac.jp:00000065","sets":["1"]},"author_link":["8581","8580","8579","8582"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-05-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"37","bibliographicPageEnd":"230","bibliographicPageStart":"225","bibliographic_titles":[{"bibliographic_title":"福井工業大学研究紀要. 第一部"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In the present study, electrothermal vaporization (ETV) with a tungsten filament was applied to axially-viewed ICP-AES for the effective introduction of small amounts of samples into the plasma. Several tungsten filaments with different diameters were examined, and consequently, the filament of 0.3mm dia. was suitable for the present work in durability and reproducibility. The possibility of the simultaneous multi-element determination with a 5-μl volume of sample solutions was found by optimizing measurement conditions such as charging voltage for a capacitor and electric current for the dry of sample solution on the filament. Although the detection limits of some elements were almost similar to those reported for conventional ETV/ICP-AES, further improvement in reproducibility is required.","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57375/00000059","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井工業大学"}]},"item_10002_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"TF00008518","subitem_relation_type_select":"NCID"}}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2868571","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 智一"}],"nameIdentifiers":[{"nameIdentifier":"8579","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"玉村, 武嗣"}],"nameIdentifiers":[{"nameIdentifier":"8580","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, Tomokazu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"8581","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tamamura, Takeshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"8582","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-12"}],"displaytype":"detail","filename":"KJ00004766968.pdf","filesize":[{"value":"464.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00004766968.pdf","url":"https://fut.repo.nii.ac.jp/record/65/files/KJ00004766968.pdf"},"version_id":"523cbbde-0df0-4cd4-9642-1b9c3540c4d5"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"軸方向観測型ICP-AESへの電熱気化法の適用と微少量試料分析への応用","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"軸方向観測型ICP-AESへの電熱気化法の適用と微少量試料分析への応用"},{"subitem_title":"Application of electrothermal vaporization using a tungsten filament to axially-viewed ICP-AES for the analysis of micro-liter samples","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-04-04"},"publish_date":"2009-04-04","publish_status":"0","recid":"65","relation_version_is_last":true,"title":["軸方向観測型ICP-AESへの電熱気化法の適用と微少量試料分析への応用"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-20T14:40:18.853462+00:00"}