{"created":"2023-06-20T13:42:54.751700+00:00","id":509,"links":{},"metadata":{"_buckets":{"deposit":"3d657dae-2bc2-436b-bd9a-6fa2a60ec855"},"_deposit":{"created_by":2,"id":"509","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"509"},"status":"published"},"_oai":{"id":"oai:fut.repo.nii.ac.jp:00000509","sets":["1"]},"author_link":["10223","10222"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-05-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"38","bibliographicPageEnd":"228","bibliographicPageStart":"221","bibliographic_titles":[{"bibliographic_title":"福井工業大学研究紀要. 第一部"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The author examined whether the meteorological data measured at Awara observation site was suitable for applying to evaluate heat fluxes and evapotranspiration based on the Bowen ration method. The obtained results as follows: 1) the calculated heat fluxes by using different sets of data are not agree with each others, and the errors are in the range of 4.1 to 11.6%, 2) the mean estimated error of daily evaporation by using the Bowen ratio is about 12%, 3) the estimated annual evaporation and water resources are 776mm and 996mm respectively.","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57375/00000503","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井工業大学"}]},"item_10002_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"TF00008962","subitem_relation_type_select":"NCID"}}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2868571","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宇治橋, 康行"}],"nameIdentifiers":[{"nameIdentifier":"10222","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ujihashi, Yasuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"10223","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-12"}],"displaytype":"detail","filename":"KJ00005074535.pdf","filesize":[{"value":"707.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00005074535.pdf","url":"https://fut.repo.nii.ac.jp/record/509/files/KJ00005074535.pdf"},"version_id":"73290b4c-6285-4620-8167-73512563de80"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"あわら学舎における2007年のフラックス観測と蒸発量評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"あわら学舎における2007年のフラックス観測と蒸発量評価"},{"subitem_title":"Measurements of heat fluxes and evaluation of evaporation at Awara campus in 2007","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-03-23"},"publish_date":"2009-03-23","publish_status":"0","recid":"509","relation_version_is_last":true,"title":["あわら学舎における2007年のフラックス観測と蒸発量評価"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-20T14:30:59.598789+00:00"}