{"created":"2024-02-09T02:32:16.719523+00:00","id":2000011,"links":{},"metadata":{"_buckets":{"deposit":"7f04efd1-ea1e-4c25-a514-7af9a3828e9c"},"_deposit":{"created_by":4,"id":"2000011","owner":"4","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2000011"},"status":"published"},"_oai":{"id":"oai:fut.repo.nii.ac.jp:02000011","sets":["1"]},"author_link":[],"control_number":"2000011","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-10-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"53","bibliographicPageEnd":"51","bibliographicPageStart":"46","bibliographic_titles":[{"bibliographic_title":"福井工業大学研究紀要"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In recent years, in radiation cancer therapy, a technique for easily visualizing radiation and evaluating accurate dose distribution is required. In our laboratory, we have developed a gel dosimeter made from PVA, KI, borax, and fructose, which have the same composition as biological components. Furthermore, in order to clarify the effect of radiation irradiation on the PVA-KI gel dosimeter, we developed a separate type in-situ measurement device that enables in-situ measurement of light absorption of the gel during irradiation. In this study, in order to clarify the characteristics of the PVA-KI gel as a dosimeter, we compared the measurement results using a separate in-situ measurement device and the measurement results using an ionization chamber. Furthermore, we tried to clarify the characteristics of γ-ray irradiation to PVA-KI gel by comparing with the results of X-ray irradiation.","subitem_description_type":"Abstract"}]},"item_10002_full_name_3":{"attribute_name":"著者(英)","attribute_value_mlt":[{"names":[{"name":"Takeyoshi,Sunagawa /Sachiko,Yoshihashi / Glenn,Harvel /Yutaro,Aoki","nameLang":"en"}]}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57375/0002000011","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井工業大学"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"砂川,武義 / 吉橋,幸子 / Glenn,Harvel / 青木,祐太郎","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-02-09"}],"filename":"kiyou5306 046-051.pdf","filesize":[{"value":"3.5 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"url":"https://fut.repo.nii.ac.jp/record/2000011/files/kiyou5306 046-051.pdf"},"version_id":"8049aa1a-d124-4872-af95-2840787f24db"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Chemical Dosimeter, Gel Dosimeter, in-situ, γ-ray","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"PVA-KIゲル線量計へのγ線照射におけるin-situ測定研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PVA-KIゲル線量計へのγ線照射におけるin-situ測定研究","subitem_title_language":"ja"},{"subitem_title":"Study of in-situ measuring device for γ-ray irradiation of PVA-KI gel dosimeter","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"4","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2024-02-09"},"publish_date":"2024-02-09","publish_status":"0","recid":"2000011","relation_version_is_last":true,"title":["PVA-KIゲル線量計へのγ線照射におけるin-situ測定研究"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2024-02-26T03:06:27.990632+00:00"}