{"created":"2023-06-20T13:43:20.026187+00:00","id":1062,"links":{},"metadata":{"_buckets":{"deposit":"f0542473-b310-47c1-abca-00f13496fe0c"},"_deposit":{"created_by":2,"id":"1062","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"1062"},"status":"published"},"_oai":{"id":"oai:fut.repo.nii.ac.jp:00001062","sets":["1"]},"author_link":["12286","12287"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-07-19","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"43","bibliographicPageEnd":"362","bibliographicPageStart":"353","bibliographic_titles":[{"bibliographic_title":"福井工業大学研究紀要"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An activated sludge system combined with a rotating biological contactor was examined on the treatability of concentrated wastewater (BOD 2,500 - 5,000mg/L). The system exhibited superior performance; BOD removal of 96 - 97% and sludge production of 11 - 17%. The rotating biological contactor was responsible for most of the pollutant removal, and consequently was able to handle such high surface loading rates of 83 - 153 gBOD/m2-d and 6.5 - 12.1 gNH4-N/m2-d.","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57375/00001056","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井工業大学"}]},"item_10002_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"TF00009515","subitem_relation_type_select":"NCID"}}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高島, 正信"}],"nameIdentifiers":[{"nameIdentifier":"12286","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takashima, Masanobu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"12287","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-12"}],"displaytype":"detail","filename":"353-362.pdf","filesize":[{"value":"5.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"353-362.pdf","url":"https://fut.repo.nii.ac.jp/record/1062/files/353-362.pdf"},"version_id":"d299ff43-aab5-4189-a657-f43181b76c35"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"concentrated wastewater","subitem_subject_scheme":"Other"},{"subitem_subject":"rotating biological contactor","subitem_subject_scheme":"Other"},{"subitem_subject":"Activated sludge","subitem_subject_scheme":"Other"},{"subitem_subject":"surface loading rate,","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"回転円板装置を用いた高濃度排水処理","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"回転円板装置を用いた高濃度排水処理"},{"subitem_title":"Concentrated wastewater treatment with rotating biological contactor","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-07-19"},"publish_date":"2013-07-19","publish_status":"0","recid":"1062","relation_version_is_last":true,"title":["回転円板装置を用いた高濃度排水処理"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-20T14:20:31.471641+00:00"}