{"created":"2023-06-20T13:42:34.755955+00:00","id":104,"links":{},"metadata":{"_buckets":{"deposit":"5eb4a061-9286-4a96-889a-a3cfcd60b9f8"},"_deposit":{"created_by":2,"id":"104","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"104"},"status":"published"},"_oai":{"id":"oai:fut.repo.nii.ac.jp:00000104","sets":["1"]},"author_link":["8775","8774","8772","8773"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-07-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"44","bibliographicPageEnd":"194","bibliographicPageStart":"190","bibliographic_titles":[{"bibliographic_title":"福井工業大学研究紀要"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An electrothermal vaporization technique with a tungsten filament (WF-ETV) was applied to inductively coupled plasma mass spectrometry (ICP-MS) in order to determine trace phosphor in environmental water. Operating parameters such as electric current for removing solvent, radio-frequency power, carrier-gas flow rate and sampling depth are optimized to minimize the relative standard deviations for signal intensities of phosphor. Background equivalent concentration of phosphor improved 10 times compared to that obtained with the conventional sample introduction technique, although further examinations in reproducibility are required for the practical application of the proposed method.","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57375/00000098","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井工業大学"}]},"item_10002_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"TF00008557","subitem_relation_type_select":"NCID"}}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田中, 智一"}],"nameIdentifiers":[{"nameIdentifier":"8772","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"天池, 智恵"}],"nameIdentifiers":[{"nameIdentifier":"8773","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, Tomokazu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"8774","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Amaike, Chie","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"8775","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-04-12"}],"displaytype":"detail","filename":"190-194.pdf","filesize":[{"value":"3.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"190-194.pdf","url":"https://fut.repo.nii.ac.jp/record/104/files/190-194.pdf"},"version_id":"25e48564-f764-4e6c-8d8e-58192884edf9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ICP-MS","subitem_subject_scheme":"Other"},{"subitem_subject":"Electrothermal Vaporization","subitem_subject_scheme":"Other"},{"subitem_subject":"Phophor","subitem_subject_scheme":"Other"},{"subitem_subject":"Environmental Water","subitem_subject_scheme":"Other"},{"subitem_subject":"Inductively Coupled Plasma","subitem_subject_scheme":"Other"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ICP質量分析法によるリン分析のためのタングステンフィラメント電熱気化法の適用","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ICP質量分析法によるリン分析のためのタングステンフィラメント電熱気化法の適用"},{"subitem_title":"Application of Tungsten-Filament Electrothermal Vaporization to ICP-Mass Spectrometry for the Determination of Trace Phosphor","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-07-09"},"publish_date":"2014-07-09","publish_status":"0","recid":"104","relation_version_is_last":true,"title":["ICP質量分析法によるリン分析のためのタングステンフィラメント電熱気化法の適用"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-20T14:39:44.444039+00:00"}